Autoclave & SterilizerACL-118

Horizontal Autoclave

Industrial-Grade Horizontal Sterilization

Designed for bulk sterilization requirements, the Autocon Horizontal Autoclave accommodates large loads of surgical instruments, culture media, and laboratory glassware. Features front-loading convenience and a robust pressure vessel design for continuous heavy-duty operation.

ISO 9001:2015 CE Certified ASME Pressure Vessel Standards

Key engineering features

  • Front-Loading DesignErgonomic horizontal loading for bulk instruments and media
  • PLC / Microprocessor ControlProgrammable cycles with automatic pressure and temperature regulation
  • Double Safety ValveDual pressure relief for redundant safety protection
  • Drying Cycle OptionPost-sterilization vacuum drying for dry loads
  • SS 316 Chamber OptionUpgrade to SS 316L for pharmaceutical-grade corrosion resistance
  • Sliding Tray SystemEasy-slide SS trays for convenient loading and unloading
Call sales
Models & capacities

Choose your size.

Standard factory models of the Horizontal Autoclave. Anything outside these — chamber size, supply, controller — can be built to order.

ParameterModelACL-118-35ModelACL-118-75ModelACL-118-150
ConfigurationHorizontal Autoclave (35L Lab Compact)Horizontal Autoclave (75L Pharma Standard)Horizontal Autoclave (150L Industrial Batch)
Chamber capacity35 Liters75 Liters150 Liters
Peak power3.0 kW4.5 kW9.0 kW
SupplySingle Phase (230V)Single Phase (230V)Three Phase (415V)
Temperature / pressure121°C to 134°C (15 - 30 psi)121°C to 134°C (15 - 30 psi)121°C to 134°C (15 - 30 psi)
Material of constructionSS 304 Heavy DutySS 316 Contact PartsSS 316L mirror polished
DimensionsØ 300 x 500 mm (Chamber)Ø 400 x 600 mm (Chamber)Ø 550 x 750 mm (Chamber)
Add to quote
Specifications

Built to a standard.

Standard factory specification

ACL-118
01Temperature Range
Up to 134°C (Configurable)
02Pressure Range
15–20 PSI (1.05–1.4 kg/cm²)
03Control System
PLC / Microprocessor with HMI Touch Screen
04Inner Chamber
Stainless Steel SS 304 / 316L
05Outer Body
MS Powder Coated / SS 304
06Loading
Front-loading with sliding trays
07Safety Features
Double safety valve, Door interlock, Low water alarm
08Power Supply
440V AC, 50 Hz, Three Phase
09Certification
ISO 9001:2015, CE Compliant

Specifications can be tailored to your facility. IQ/OQ/PQ protocols are available.

Electrical load

What will the Horizontal Autoclave need from your supply?

50L
10 L compact300 L industrial
134°C
100 °C134 °C · 30 psi
8h
1 h24 h

Estimated peak power

4.8kW

Supply
Single phase, 230 V AC
Operating current
21 A
Recommended MCB
27A 1-pole
Daily consumption
25 kWh

Indicative values for planning. Custom transformers and power conditioning are available on request.

Utility & energy ROI

Calculate the 3-year running cost of the Horizontal Autoclave.

Power savings, closed-loop water savings and payback period.

Open calculator
Configured together

Microbiology & Aseptic Preparation Suite

Frequently configured together for microbiological media prep & testing

Standard microbiology workflow requires sterile media preparation in autoclaves, aseptic inoculation under Laminar Air Flow, and precise temperature-controlled incubation.

  • Laminar Air FlowACL-113

    Laminar Air Flow

    Clean Room Equipments

  • BOD IncubatorACL-106

    BOD Incubator

    Freezers & Cold Storage

  • Water BathACL-124

    Water Bath

    General

Applications

  • Central Sterile Departments,
  • Pharmaceutical Manufacturing,
  • Biotech Labs,
  • Hospital CSSD,
  • Research Institutes