Clean Room EquipmentsACL-114

Bio Safety Cabinet

Class II Biological Safety for Hazardous Procedures

The Autocon Bio Safety Cabinet Class II provides dual protection — safeguarding both the operator and the samples from cross-contamination. HEPA-filtered downflow and inflow curtain create a containment barrier for handling pathogenic materials safely.

ISO 9001:2015 CE Certified NSF/ANSI 49 Guidelines

Key engineering features

  • Class II Type A2Dual HEPA filtration protects operator, product, and environment
  • Inflow Air CurtainNegative pressure containment prevents aerosol escape
  • Motorized Front SashElectric sash with position sensor and auto-close safety
  • HEPA Exhaust FilterFiltered exhaust ensures contaminated air never reaches the room
  • Ergonomic DesignAngled front and armrest for comfortable extended use
  • UV + Fluorescent LampDual lighting system with independent timer controls
Call sales
Models & capacities

Choose your size.

Standard factory models of the Bio Safety Cabinet. Anything outside these — chamber size, supply, controller — can be built to order.

ParameterModelACL-114-SModelACL-114-PRO
ConfigurationBio Safety Cabinet (Standard Build)Bio Safety Cabinet (Pro Custom Build)
Chamber capacityStandard Lab VolumeExpanded Capacity
Peak power2.0 kW4.5 kW
SupplySingle Phase (230V)Three Phase (415V)
Temperature / pressureStandard Operating RangeExtended Range (-40°C to +250°C)
Material of constructionSS 304 Contact PartsSS 316L High Grade
Dimensions400 x 400 x 600 mm600 x 600 x 800 mm
Add to quote
Specifications

Built to a standard.

Standard factory specification

ACL-114
01Class
Class II Type A2
02Protection
Personnel, Product, and Environment
03HEPA Filter (Supply)
99.99% @ 0.3 μm
04HEPA Filter (Exhaust)
99.99% @ 0.3 μm
05Inflow Velocity
≥ 0.53 m/s
06Downflow Velocity
0.25 – 0.35 m/s
07Work Surface
Stainless Steel SS 304
08Noise Level
< 65 dB(A)
09Power Supply
230V AC, 50 Hz

Specifications can be tailored to your facility. IQ/OQ/PQ protocols are available.

Electrical load

What will the Bio Safety Cabinet need from your supply?

50L
10 L compact300 L industrial
150°C
−30 °C250 °C
8h
1 h24 h

Estimated peak power

2.3kW

Supply
Single phase, 230 V AC
Operating current
10 A
Recommended MCB
13A 1-pole
Daily consumption
12 kWh

Indicative values for planning. Custom transformers and power conditioning are available on request.

Configured together

Sterile Processing & Biosafety Suite

Essential companions for clean air handling & biological workflows

Cleanroom sample processing pairs laminar airflow hoods with autoclaves for sterile instrument cycle and incubators for sterility verification testing.

  • Vertical AutoclaveACL-116

    Vertical Autoclave

    Autoclave & Sterilizer

  • BOD IncubatorACL-106

    BOD Incubator

    Freezers & Cold Storage

  • Lab RefrigeratorACL-105

    Lab Refrigerator

    Freezers & Cold Storage

Applications

  • BSL-2 Labs,
  • Virology Research,
  • Oncology Drug Prep,
  • Pathology Labs,
  • Clinical Diagnostics